Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-60
display errors 
8
Form output
After you complete the options screen, the system displays a 1- or 2-page 
Hardware Error Report. To toggle between the pages and to exit the report, use 
the keys described below:
For 513 and 715 terminals, use 
F8
 for 
NEXT PAGE
 and 
PREV PAGE 
commands
For all other terminals, use 
F7
 for 
NEXT PAGE
 and 
PREV PAGE 
commands
Use 
Esc
 for the 
CANCEL
 command
The figure below is an example of an Hardware Error Report -- Active Alarms, 
without
 the high-resolution qualifier in the command line.
Field descriptions
Port
Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as: 
cabinet-carrier-[slot]-[circuit]. Example: 01C702.
Port network locations display as: port network number-bus. 
Example: 
PN 02B
. PN 02 = Port Network (PN) number and A 
or B = bus.
Maintenance 
Name
Lists the logical name of the maintenance object with an error 
logged against it.
Alt Name
Identifies the location of maintenance object, as follows:
Station = extension number 
Trunk = Group number (78/__) or group and member 
numbers (78/01) 
Private CO Line = private CO line (P) and group number 
(P/xxx)
 
 display errors                                                   Page  1   SPE A
                      HARDWARE ERROR REPORT - ACTIVE ALARMS
 Port      Mtce     Alt     Err   Aux     First       Last      Err Err Rt/ Al Ac
           Name     Name    Type  Data    Occur       Occur     Cnt Rt  Hr  St 
 01C0702   ANL-LINE 311     257         01/31/09:20 01/31/20:26 255 256 255 a  y
 01C0701   ANL-LINE 1051    257         01/31/20:26 01/31/20:26 4   0   4   a  y
 01C0703   ANL-LINE 1053    257         01/31/20:26 01/31/20:26 4   0   4   a  y
 01A       TDM-CLK          0     0     01/31/20:34 01/31/20:34 1   0   1   a  n
 01C1505   CO-TRK   078/001 3329  57408 01/31/20:26 01/31/20:27 5   300 5   a  y
 01C1505   CO-TRK   078/001 1537        01/31/20:26 01/31/20:28 5   150 5   a  y
 02A0201   TONE-PT          0           01/31/20:34 01/31/20:34 1   0   1   a  y
 PN 02B    TDM-BUS          18    0     01/31/14:53 01/31/21:12 1   0   1   a  n
 Command successfully completed