Maintenance Commands and Trouble-Clearing Aids 
Page 8-78
display system-parameters maintenance 
8
Field descriptions
Defaults for data entry fields are listed in parentheses.
Product 
Identification
10-digit number (starting with 1) that identifies the switch to an 
Operations Support System (OSS), for example, INADS.
First OSS Telephone 
Number
First telephone number that the switch dials to report alarms; 
must be obtained from the National Customer Support Center 
(NCSC) or the TSC. (
#
 and 
*
 are not allowed in the telephone 
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the first OSS. 
(yes)
Second OSS Telephone 
Number
Second telephone number that the switch dials to report alarms; 
must be obtained from the National Customer Support Center 
(NCSC) or the TSC. (
#
 and 
*
 are not allowed in the telephone 
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the second 
OSS. (no)
  
   change system-parameters maintenance           Page 3 of 3
 
           MAINTENANCE-RELATED SYSTEM PARAMETERS
Modem Connection: external 
Data Bits: 8 
Parity: none 
Modem Name: intel 
RTS/CTS Enabled: \Q3 
Auto Answer Ring Count (rings): S0=10 
Asynchronous Data Mode: &M0&Q0 
Dial Type: T 
DTE Auto-Data Speed: \J1 
Adjustable Make/Break Ratio: &P0 
Disable Data Compression: H0%C0 
Dial Command: D 
Enable Error Control: \N3 
No Answer Time-out: S7=255 
Misc. Init. Param: ____________________
Help/Error Message Line 
Command Line