Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-78
display system-parameters maintenance
8
Field descriptions
Defaults for data entry fields are listed in parentheses.
Product
Identification
Identification
10-digit number (starting with 1) that identifies the switch to an
Operations Support System (OSS), for example, INADS.
Operations Support System (OSS), for example, INADS.
First OSS Telephone
Number
Number
First telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
#
and
*
are not allowed in the telephone
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the first OSS.
(yes)
(yes)
Second OSS Telephone
Number
Number
Second telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
#
and
*
are not allowed in the telephone
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the second
OSS. (no)
OSS. (no)
change system-parameters maintenance Page 3 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
Modem Connection: external
Data Bits: 8
Parity: none
Modem Name: intel
RTS/CTS Enabled: \Q3
Auto Answer Ring Count (rings): S0=10
Asynchronous Data Mode: &M0&Q0
Dial Type: T
DTE Auto-Data Speed: \J1
Adjustable Make/Break Ratio: &P0
Disable Data Compression: H0%C0
Dial Command: D
Enable Error Control: \N3
No Answer Time-out: S7=255
Misc. Init. Param: ____________________
Help/Error Message Line
Command Line
Command Line