Page 8-158
monitor security-violations 
8
monitor security-violations
This command displays information about failed attempts to access the system, 
including the time of the violation, the login entered, and the port accessed 
during the failed login attempt. The system logs trunk group numbers, members, 
and extensions for remote access violations. The system logs remote and local 
invalid access attempts with a total of 16 entries maintained for each access 
type. This online status report automatically updates every 30 seconds until the 
command is canceled by pressing the CANCEL key.
Emerg Trans
Current setting of the emergency transfer switch for each cabinet. Five 
options are available: auto-on (“auto+” or “a+”), auto-off (“auto-” or 
“a-”), “on”, “off”, and “n.a.”. If “auto+” or “auto-” option are enabled, 
emergency transfers automatically activate when cabinets fail (“+” 
indicates that emergency transfer is activated, while “-” indicates that 
emergency transfer is inactive). When “on” is displayed, emergency 
transfer automatically activates. The “off” option shows that cabinets 
cannot activate emergency transfers. In duplicated SPE systems, 
switch settings for both processors of the PPN (cabinet 1) display. In 
this case, “auto+” is abbreviated “a+”, “auto-” is d “a-”, and “off” is 
“of”. “on” does not changed. If “n.a.” displays, emergency transfer 
switch settings are not available.
Mj
Number of major alarms associated with the cabinet. An asterisk fills 
the field when the number exceeds 99.
Mn
Number of minor alarms associated with the cabinet. An asterisk fills 
the field when the number exceeds 99.
Wn
Number of warnings associated with the cabinet. An asterisk fills the 
field when the number exceeds 99.
PNC
Displays current Port Network Connectivity (PNC) status for each port 
network within a cabinet. When multiple port networks exist within a 
cabinet, a slash separates Carriers A, B, and C (listed first) from 
Carriers D and E (up/up). Availability of the Expansion Archangel Link 
(EAL) determines the PNC status of a port network. “Up” denotes EAL 
availability. When the EAL is not available, then “dn” (down) displays.
Time of Day
Displays current time of day acquired from the system.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
monitor 
security- 
violations
print
Report sent to printer.
Examples:
monitor security-violations
monitor security-violations print
init
inads
craft
cust
rcust
bcms
browse
none
none