Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-182
release pri-endpoint
8
Output
The following output example is a display of the
release port 1c0701
command.
Assume that the port in cabinet 1, carrier c, slot 7, circuit 1 is an analog port.
Field descriptions
release pri-endpoint
The
release-PRI endpoint
command removes PRI endpoint ports (B-channels)
associated with specified PRI endpoint from maintenance busy states. Periodic
and scheduled tests resume on released ports. The switch attempts to negotiate
and scheduled tests resume on released ports. The switch attempts to negotiate
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
Interactions
release port
location
Physical location:
PCsspp
Examples:
release port 01c1101
release port 02c1501
release port 02c1501
init
inads
craft
inads
craft
none
none
Port
Port address (cabinet-carrier-slot-circuit) of released maintenance
object.
object.
Maintenance Name
The type of maintenance object that is being released.
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
release port 01C0701
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C0701 ANL-LINE PASS
01C0701 ANL-LINE PASS
Command successfully completed