Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-185
release spe-standby 
8
release spe-standby
The 
release spe-standby
 command removes busyout statuses of standby SPEs. 
Memory shadowing restores, a memory refresh of the standby SPE occurs, and 1 
minute later the equivalent of scheduled standby SPE maintenance returns the 
standby SPE’s Fault Severity Level to its appropriate value.
Standby SPE releases are allowed if communication to the standby is down.
Feature Interactions
When standby SPEs release a memory, a refresh executes and the standby Fault 
Severity Level lowers to its appropriate level. One minute later, the equivalent of 
scheduled standby SPE maintenance executes and a spontaneous SPE 
interchange might occur, depending of Fault Severity Levels of the two SPE’s.
If the standby SPE is in poor health, memory shadowing must not enable 
(communication to the standby is impossible, if it is enabled). Then the standby 
SPE releases successfully.
Output
The following output example is a display of the
 release spe-standby
 command 
and assumes that the standby SPE is located in carrier “B.” 
Field descriptions
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
release 
spe-standby
init
inads
craft
none
see below
Port
Port address displays the standby SPE’s cabinet and carrier 
location. (01A or 01B)
Maintenance Name
STBY-SPE
 
 release spe-standby              SPE A
                          COMMAND RESULTS
 Port  Maintenance Name    Alt. Name    Result    Error Code
 01B       STBY-SPE                     PASS
 Command successfully completed