Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-206
set options 
8
Major off-board trunk alarms
Minor off-board trunk alarms
Technicians assign alarm severity options to the following Adjunct categories:
Major on-board adjunct alarms
Major off-board adjunct alarms
Minor on-board adjunct alarms
Minor of-board adjunct alarms
Technicians can administer options for Minor off-board DS1 Interface circuit 
pack alarms and Minor off-board Memory Card Capacity Alarms on a 
system-wide basis.
The system inspects alarm reporting options information in the Alarm Reporting 
Options Form as translation data and preserves it through all restart levels.
This command affects the MO alarming listed below. Neither the trunk nor the 
station category applies to alarms raised on the common portion of the circuit 
pack.
If the option associated with the alarm type is set to “n,” the system drops the 
alarm report. Alarm error information remains intact, but no records of alarms and 
no LEDs light on the port circuit pack, the Maintenance circuit pack, the 
attendant console, or alarm reporting station to indicate a problem.
If technicians set the option “warning” or “report,” port circuit pack LEDs and 
LEDs on the Maintenance circuit pack are affected the same as warning alarms.
Default parameters are:
The system downgrades all station, trunk (except on-board trunk alarms), 
and Minor DS1-BD alarms to warning alarms.
On-board Major and Minor trunk alarms, and the Memory Card Capacity 
alarm continue to raise alarms and report to INADS.
Station MOs Affected By This Command
NOTE:
Although alarms on some MOs appear as warnings, they should be 
investigated with user-reported problems.
Analog Lines (ANL-LINE, ANL-NE-L, ANL-16-L)
Digital Lines (DIG-LINE)
Hybrid Lines (HYB-LINE)
MET Lines (MET-LINE)