Maintenance Architecture 
Page 1-16
Protocols 
1
Quantization Distortion Loss
 lists the quantization distortion loss in the system for analog port to 
analog port.
 lists the quantization distortion loss in the system for analog port to 
digital port and digital port to analog port.
Terminating Impedance: 600 Ohms nominal
Trunk balance impedance (selectable): 600 Ohms nominal or complex Z [350 Ohms + (1 
k Ohms in parallel with 0.215uF)]
Impulse Noise
On 95% or more of all connections, the impulse noise is 0 count (hits) in five 
minutes at +55 dBrnC (decibels above reference noise with C-filter) during the 
busy hour.
Table 1-10.
Quantization Distortion Loss
Analog Port-to-Analog Port
Signal Level
Distortion Loss
0 to -30 dBm0
>33 dB
-40 dBm0
>27 dB
-45 dBm0
>22 dB
Table 1-11.
Quantization Distortion Loss
Analog Port-to-Digital Port or 
Digital Port-to-Analog Port
Signal Level
Distortion Loss
0 to -30 dBm0
>35 dB
-40 dBm0
>29 dB
-45 dBm0
>25 dB