Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-307
status system
8
SPE Modes
MODE
■
active
: Expansion Interface Link is in-service and providing
the active connectivity between the two cabinets.
■
standby
: Expansion Interface Link is in-service and ready to
provide connectivity between the two cabinets should the active
link fail.
link fail.
■
down
: Expansion Interface Link is out-of-service and cannot
provide connectivity between the two cabinets.
■
<blank> Expansion Interface Link does not exist
CABINET TYPE
■
MCC
: Medium Carrier Cabinet (up to 5 carriers, simplex or
duplex as a PPN)
■
SCC
: Single Carrier Cabinet (up to 4 carriers, simplex or duplex
as a PPN)
■
EMCC
: Enhanced Medium Carrier Cabinet (up to 5 carriers, can
only be a simplex or duplex PPN cabinet)
■
ESCC
: Enhanced Medium Carrier Cabinet (up to 4 carriers, can
only be a simplex or duplex PPN cabinet)
■
MICRO
: Micro or wall-mounted cabinet (always exists alone as
an A carrier in a simplex PPN)
Simplex SPE Modes
active
1A
SPE in a simplex system is always the active SPE
blank
No 1B SPE in a simplex system
Duplex Active SPE Modes
active
This SPE is the active SPE.
active/
override-on
This the active SPE; however, it was forced active through a
reset system interchange health-override
command.
selected
This is the active SPE; however, the SPE select switches do
not
allow this to become the standby SPE.
Duplex Standby SPE Modes
Standby Mode
Standby Mode
standby
SPE is held reset, memory shadowed from the active SPE, and
ready to take over as the active SPE.
ready to take over as the active SPE.
Busyout Modes
busyout/idle
SPE busied out and there is no current maintenance activity.
The active SPE can be either active or selected.
The active SPE can be either active or selected.