Page 8-307
status system 
8
SPE Modes
MODE
active
: Expansion Interface Link is in-service and providing 
the active connectivity between the two cabinets.
standby
: Expansion Interface Link is in-service and ready to 
provide connectivity between the two cabinets should the active 
link fail.
down
: Expansion Interface Link is out-of-service and cannot 
provide connectivity between the two cabinets.
<blank> Expansion Interface Link does not exist
CABINET TYPE
MCC
: Medium Carrier Cabinet (up to 5 carriers, simplex or 
duplex as a PPN)
SCC
: Single Carrier Cabinet (up to 4 carriers, simplex or duplex 
as a PPN)
EMCC
: Enhanced Medium Carrier Cabinet (up to 5 carriers, can 
only be a simplex or duplex PPN cabinet)
ESCC
: Enhanced Medium Carrier Cabinet (up to 4 carriers, can 
only be a simplex or duplex PPN cabinet)
MICRO
: Micro or wall-mounted cabinet (always exists alone as 
an A carrier in a simplex PPN)
Simplex SPE Modes
active
1A
 
SPE in a simplex system is always the active SPE
blank
No 1B SPE in a simplex system
Duplex Active SPE Modes
active
This SPE is the active SPE.
active/ 
override-on
This the active SPE; however, it was forced active through a 
reset system interchange health-override
 command.
selected
This is the active SPE; however, the SPE select switches do 
not
 allow this to become the standby SPE.
Duplex Standby SPE Modes
    Standby Mode
standby
SPE is held reset, memory shadowed from the active SPE, and 
ready to take over as the active SPE.
    Busyout Modes
busyout/idle
SPE busied out and there is no current maintenance activity. 
The active SPE can be either active or selected.