August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-311
status trunk 
8
Field descriptions (group/member)
Group only
The following example shows the output from the 
status trunk 78
 (trunk group 
only) command.
Trunk 
Group/Member
Trunk group number/group member number (1-99/1-99)
Port
Port location (cabinet-carrier-slot-circuit)
Signaling 
Group ID
If trunk is ISDN, then this field displays the number of the ISDN 
Signaling Group to which this group belongs; otherwise, the field is 
blank.
Connected 
Ports
Port locations (cabinet-carrier-slot-circuit) connected to the trunk
Service State
Trunk service state:
in-service/active, in-service/idle, out-of-service-NE, 
out-of-service-FE, maint-NE/active, maint-FE/active, maint-NE/idle, 
and maint-FE/idle.
NE (Near End; switch) and FE (Far End; PRI terminal adapter or any 
device that terminates the D-channel signaling) refer to which 
“end” of the B-channel has placed the facility in the current state.
Maintenance 
Busy
Whether any maintenance testing is being performed
CA-TSC State
State of the temporary signaling connection (used to pass call 
information over PRI signaling links)
 
 status trunk 78/1
                            TRUNK STATUS
 Trunk Group/Member: 078/001            Service State: in-service/idle
               Port: 01C1505         Maintenance Busy? no
 Signaling Group ID:                     CA-TSC State:
    Connected Ports: