Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-347
test hardware-group 
8
Feature Interactions
1.
The type of carrier may be port, or processor. In the case of a port carrier, all universal port and tone-clock boards (see 
reference 4) and its affiliated MOs residing in the specified carrier are tested. For a processor carrier, all SPE complex 
and tone-clock boards and its affiliated MOs are tested.
2.
All PN and PNC related MOs plus cabinet specific MOs, including maintenance boards and environment (ring generator, 
battery, power, emergency transfer, external alarms, fans, and temperature) are tested if they reside in the 
specified’cabinet location’.
3.
All MOs on the specified ’board location’ including ports are tested.
4.
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
test hardware-group
system
carrier 
location
cabinet 
location
board 
location
print
schedule
System-wide test of all 
hardware-groups
Carrier address: cabinet (1-3), 
carrier (A-E)
1
Cabinet address (1-3)
2
Board address in PCSS format
3
Output sent to printer
Command validated and then a 
scheduling form displays to 
schedule execution of the command. 
The command is then placed in the 
command queue and is executed at 
the specified time. The information 
displayed by the command is sent to 
the system printer instead of the 
screen.
4
Examples:
test hardware-group system
test hardware-group system print
test hardware-group carrier 1a
test hardware-group carrier 1a 
schedule
test hardware-group cabinet 2
test hardware-group board 01c07
test hardware-group board 01c07 
schedule
test hardware-group spe
test hardware-group spe print
test hardware-group spe schedule
init
inads
Test 
sequence 
= short; 
repeat = 1
See below
test 
hardware-group
Only one 
test hardware-group
 command can be active at any 
given time.