Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-360
test led
8
On a duplex PPN, only the long option tests the leds in the standby SPE. When
executing the
executing the
test led long
command, the standby Processor, Memory, and
Packet Control circuit pack LEDs can take up to 20 seconds to light.
The following LEDs are NOT lighted by the
test led
command:
■
SPE Select LEDs on the Duplication Interface Circuit Packs
■
Power Unit LEDs
■
Yellow (amber) LED on the tape drive
Output
If the command is successful,
Command successfully completed
displays.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
Interactions
test led
all
cabinet
number
number
short
long
repeat
number
number
All LEDs in all carriers are tested
Cabinet number (each carrier
tested sequentially)
tested sequentially)
Simplex: short and long option are
identical and turn on and off all
leds in the specified port network.
Duplex: short option does
identical and turn on and off all
leds in the specified port network.
Duplex: short option does
not
affect the leds in the standby SPE
carrier in the PPN.
carrier in the PPN.
Simplex: short and long option are
identical and turn on and off all
leds in the specified port network.
Duplex: long option
identical and turn on and off all
leds in the specified port network.
Duplex: long option
does
affects
the leds in the standby SPE carrier
in the PPN.
in the PPN.
Number of times each test in the
sequence is repeated (1-100)
sequence is repeated (1-100)
Examples:
test led
test led all r 2
test led cabinet 1
test led c 1
test led 1 long
test led all r 2
test led cabinet 1
test led c 1
test led 1 long
init
inads
craft
inads
craft
all; repeat
= 1; test
sequence
= short in a
duplex
system
= 1; test
sequence
= short in a
duplex
system
none