Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-360
test led 
8
On a duplex PPN, only the long option tests the leds in the standby SPE. When 
executing the 
test led long
 command, the standby Processor, Memory, and 
Packet Control circuit pack LEDs can take up to 20 seconds to light.
The following LEDs are NOT lighted by the 
test led
 command:
SPE Select LEDs on the Duplication Interface Circuit Packs
Power Unit LEDs
Yellow (amber) LED on the tape drive
Output
If the command is successful, 
Command successfully completed
 displays.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
test led
all
cabinet 
number
short
long
repeat 
number
All LEDs in all carriers are tested
Cabinet number (each carrier 
tested sequentially)
Simplex: short and long option are 
identical and turn on and off all 
leds in the specified port network.
Duplex: short option does 
not
 
affect the leds in the standby SPE 
carrier in the PPN.
Simplex: short and long option are 
identical and turn on and off all 
leds in the specified port network.
Duplex: long option 
does
 affects 
the leds in the standby SPE carrier 
in the PPN.
Number of times each test in the 
sequence is repeated (1-100)
Examples:
test led
test led all r 2
test led cabinet 1
test led c 1
test led 1 long
init
inads
craft
all; repeat 
= 1; test 
sequence 
= short in a 
duplex 
system
none