Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-363
test maintenance 
8
link, reset, and sanity functions on the EPN maintenance circuit pack. The long 
test resets the EPN maintenance circuit pack, causing the EPNSAT link to be 
dropped and is destructive.
Feature Interactions
The last test in the long test sequence on EPN maintenance circuit packs drops 
the EPNSAT link.
1.
If no alarms are registered against the maintenance object then the test sequence is run only once. The
 long 
clear
 option forces a clear of all alarms if no errors are encountered during testing. The 
short clear
 option only 
clears alarms pertinent to tests in the short sequence.
2.
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
test 
maintenance
location
short
long
repeat 
number
clear
schedule
Physical location of the 
maintenance circuit pack: (2-3)
Option for a brief series of 
nondestructive diagnostic tests.
Option for a longer, more 
comprehensive series of both 
destructive and nondestructive 
diagnostic tests.
Number of times each test in the 
sequence is repeated (1-100)
This option causes the test 
sequence (short or long) to repeat 
until the alarm (if any) is cleared or 
a single test in the sequence fails.
1
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue and 
is executed at the specified time. 
The information displayed by the 
command is sent to the system 
printer instead of the screen.
2
Examples:
test maintenance 2
test maintenance 3 schedule
test maintenance 2 sh
test maintenance 2 l c
init
inads
craft
Test 
sequence = 
short; 
repeat = 1
See below