Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-366
test modem-pool 
8
Defaults
The cabinet default is always 1. For SPE simplex systems, the default carrier is 
the “a” carrier; for SPE duplex systems, there is no default carrier. The defaults 
for the remaining parameters are short with a repeat of 1.
Output
The following example show the output for the 
test memory 1b
 command. The 
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
test modem-pool
This command performs hardware diagnostic tests on the specified modem pool 
group or an individual member of a specified group (Combined or Integrated). A 
Combined modem-pool group consists of pairs of Analog and Digital Line ports. 
One pair of Analog and Digital Line ports used for modem-pooling is called a 
conversion resource. An Integrated group consists of modem-pool circuit packs, 
each containing two conversion resources. Therefore, when a member number is 
specified for a Combined modem-pool group, one conversion resource is tested, 
and when a member number is specified for an Integrated modem-pool group, 
two conversion resources are tested.
Port
The port address (cabinet-carrier) 
Maintenance 
Name
The name of maintenance object being tested is MEMORY.
Alt. Name
Not applicable.
Test No.
The test being executed
Result
The result of the test: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test memory 1b
                           TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
   01B     MEM-BD                      87       PASS
   01B     MEM-BD                      631      PASS
 Command Successfully Completed