Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-377
test pms-link 
8
Output
The following example shows the output for the 
test pms-link long
 command. 
The responses display on a test-by-test basis with one line of data for each test 
result.
Field descriptions
Port
Always blank
Maintenance 
Name
Always PMS-LINK
Alt. Name
Not applicable.
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test pms-link long
                               TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
           PMS-LINK                    214      PASS
 Command Successfully Completed