DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-382
test processor 
8
test processor
This command performs hardware diagnostic tests on a specified processor 
circuit pack.
Defaults
For SPE simplex systems, the location is optional and defaults to cabinet 1, 
carrier a. For SPE duplex systems, the cabinet default is again cabinet 1, but 
there is no default for the carrier. Defaults for the remaining parameters are short 
with a repeat of 1.
1.
If no alarms are registered against the maintenance object then the test sequence is run only once. The
 long 
clear
 option forces a clear of all alarms if no errors are encountered during testing. The 
short clear
 option only 
clears alarms pertinent to tests in the short sequence.
2.
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
test processor
location
short
long
clear
schedule
Cabinet number (optional for 
simplex) and carrier letter (optional 
a
 for simplex; 
a
 or 
b
 for duplex). 
Option for a brief series of 
nondestructive diagnostic tests.
Option for a longer, more 
comprehensive series of both 
destructive and nondestructive 
diagnostic tests.
This option causes the test 
sequence (short or long) to repeat 
until the alarm (if any) is cleared or 
a single test in the sequence fails.
1
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue and 
is executed at the specified time. 
The information displayed by the 
command is sent to the system 
printer instead of the screen.
2
Examples:
test processor 
test processor schedule
test processor a
test processor 1a
test processor b sh
test processor a l c
init
inads
craft
See 
below
none