Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-391
test station 
8
Field descriptions
test station
This command performs hardware diagnostic tests on an individual port circuit 
assigned to that extension. The technician must specify the extension and a 
translation is automatically done to the physical port location.
Port
The port address: cabinet-carrier-slot-circuit
Maintenance 
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate means of identifying the maintenance object. This field 
contains the extension when the object is a data module.
Test No
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test spe-standby                               SPE A
                             TEST RESULTS
 
 Port    Maintenance Name Alt. Name Test No. Result       Error Code
 01B     SHDW-CIR                   285                   PASS
 01B     SHDW-CIR                   284                   PASS
 01B     SPE-SELECT                 278                   PASS
 01B     DUPINT                     315                   PASS
  .        .                         .                      .
  .        .                         .                      .
  .        .                         .                      .
 Command Successfully Completed