Maintenance Commands and Trouble-Clearing Aids 
Page 8-404
upgrade software 
8
Feature Interactions
System Restarts
An upgrade causes a system restart: simplex systems perform a Level-4 restart, 
and duplex systems perform a Level-2 SPE-interchange after the standby is 
upgraded through a Level-4 restart.
Initcauses
Executing 
display initcauses
 shows the software upgrade and the system reset 
level.
Multi-User Contention
When this command is executing, all other maintenance commands are blocked. 
Exceptions to these are most of the status or display commands. All 
administration commands are not blocked. It is the user’s responsibility to make 
sure that no new translations are added between the last 
save translation
 
operation and the completion of the 
upgrade software
 command.
Recent Change History Log
The 
upgrade software
 command does not log for both simplex and duplex 
systems. This is due to the clearing of memory during the level 4 reset.
Periodic and Scheduled Maintenance
Periodic and scheduled maintenance is suspended during the upgrade.
Error and Alarm Log
Error and alarm logs before the software upgrade are lost.
Demand Busyout Objects
Maintenance objects that have been demand busyout are released when the 
processor reboots or interchanges during the software upgrade. If the command 
is cancelled before the actual reboot or interchange starts, then all demand 
busyout objects status are preserved.
Data Consistency between SPEs
Data consistency alarms are generated if the software in the active and standby 