Page 10-23
ADX8D-PT (AUDIX Digital Port) 
10
Electronic Power Feed Test (#11)
Station Lamp Updates Test (#16)
Station (Digital) Audits Test (#17)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and 
that it never crosses over to time slots reserved for other connections. If the NPE 
is not working correctly, one-way and noisy connections may be observed. This 
test is part of a port’s Long Test Sequence, and it takes about 20 to 30 seconds 
to complete. 
Crosstalk testing is performed on both the primary information channel (voice) 
and on the secondary information channel (data) associated with each DEFINITY 
AUDIX port. If this test fails on either channel, the voice port is taken 
out-of-service.
Table 10-10.
TEST #9 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/Recommendation
1
ABORT
During testing of the primary information channel, system resources may not 
have been available. Also, the port may have been busy during the test.
1. Check the port status. Use the 
display port PCSSpp
 command to 
determine the voice port extension of the port. Use the 
status station
 
command to determine the service state of the port. If the service state 
indicates that the port is in use, you must wait until the port is idle. When 
the port is idle, try (a).
2
ABORT
System resources may not have been available, or the port may have been 
busy during the test. Try (a).
1000
ABORT
System resources required to run this test are not available. The port may be 
in use. Use the 
display port PCSSpp
 command to determine the voice port 
extension of the port. Use the 
status station
 command to determine the 
service state of the port. If the service state indicates that the port is in use, 
you must wait until the port is idle before retesting. Try (a).
1001
ABORT
System resources required to run this test are not available. Try (a).
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service due to 
TDM-BUS errors. Refer to “TDM-BUS” to diagnose any active TDM-BUS 
errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic, 
try (a).
Continued on next page