August 1997
Maintenance Object Repair Procedures
Page 10-45
ANL-16-L (16-Port Neon Analog Line)
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short
Execute the short
test port PCSSpp
command, and follow the procedure
for the results of Test #48.
■
40960
—
indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options
command.
Table 10-19.
16-Port Neon Analog Line Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960
40977
40977
none
15 (b)
Any
Audits and Updates
Test (#36)
Test (#36)
18
0
busyout station
<extension>
<extension>
WRN
ON
release station <extension>
130 (c)
None
WRN
ON
test port PCSSpp sh
257 (d)
40973
none
513 (e)
Station Present Test
(#48)
(#48)
WRN
OFF
test port PCSSpp sh r 2
769
Battery Feed Test
(#35)
(#35)
MIN/WRN
2
ON
test port PCSSpp sh r 2
1025
Loop Around Test
(#161)
(#161)
MIN/WRN
2
ON
test port PCSSpp l r 2
1281
Conference Test (#7)
MIN/WRN
2
ON
test port PCSSpp l r 2
1537
NPE Crosstalk Test
(#6)
(#6)
MIN/WRN
2
ON
test port PCSSpp l r 2