Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-65
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. These are in-line errors and can only be resolved over time.
40960
indicates that too many simultaneous incoming ringing 
attempts were made on this board. Only four ports on a board may 
be ringing simultaneously. A fifth incoming call will cause an inline 
error from the board.
40975
indicates that the terminal equipment was on-hook when 
ring-tip was detected during ringing. This usually indicates a failure 
in the terminal equipment or the type of terminal has a low ringer 
impedance. Call the terminal equipment and verify that the terminal 
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used 
in the 
set options
 command.
Table 10-26.
8-Port Analog Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960 
40975 
40977
None
15 (b)
Any
Audits and Updates 
Test (#36)
18
0
busyout station 
<extension>
WRN
OFF
release station <extension>
130(c)
None
WRN
ON
test port PCSSpp sh
257 (d)
Station Present Test 
(#48)
WRN
OFF
test port PCSSpp sh r 3
513
Battery Feed Test 
(#35)
MIN/ 
WRN
2
ON
test port PCSSpp sh r 2
769 (e)
Loop Around and 
Conference Test(#47)
test port PCSSpp l r 3
1025
NPE Crosstalk Test 
(#6)
MIN/WR
N
2
ON
test port PCSSpp l r 3
1281 (f)
1793 (f)