ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
Station Present Test (also called Ringing 
Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and 
detects that current flows. This test is to ascertain whether or not terminal 
equipment is connected to the port.
This test may cause some terminal equipment to ring briefly during daily 
maintenance. If this ringing is disturbing the customer or the terminal equipment, 
it should be disabled using the Tests field of the station administration screen. 
However, on some releases of the software, this action disables Tests #6, #47, 
and #35 as well as Test #48.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-31.
TEST #48 Station Present Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
Continued on next page