Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-109
ANN-PT (Announcement Port) 
10
b. This error is logged and the port is alarmed when an alarm is raised on the 
Announcement circuit pack because of a faulty condition with a common 
circuit pack resource. Any one of the following alarmed errors on the 
Announcement circuit pack causes this error to be logged against the 
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD 
(Announcement Circuit Pack) Maintenance documentation to resolve 
these alarms. When the corresponding circuit pack alarm is cleared, this 
alarm clears.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Channel Administration Memory Array (CAMA) Test,
 for example, you may also 
clear errors generated from other tests in the testing sequence.
Channel Administration Memory Array (CAMA) 
Test (#205)
This test is a memory device that stores information used to control the 140AY 
device. The Angel asynchronously feeds the CAMA with the control information. 
During the CAMA test, the Angel writes patterns into the CAMA, reads them 
back, and verifies that they match. If the patterns do not match, the test fails. This 
test is run periodically by the switch maintenance and by the Announcement 
circuit pack in the background.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long 
Test 
Sequence
D/ND
1
Channel Administration Memory Array 
(CAMA) Test (#205)
X
ND
Playback Speech Memory Array (PSMA) 
Test (#206)
X
X
ND
140AY Channel Sanity Inquiry Test (#222)
X
X
ND