Maintenance Object Repair Procedures 
Page 10-141
ASAI-PT 
10
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter 
maintained on the ASAI circuit pack. This counter is incremented by the circuit 
pack when it detects a Layer 1 transmission problem. The test passes if the value 
of the counter is 0 (that is, the error is cleared). If the counter is not zero, the test 
fails, and the value of the counter is displayed in the Error Code field.
This error is most likely due to a problem with the wiring or adjunct (verify that the 
wiring meets the configuration rules defined in 
DEFINITY Communications 
System Generic 1 and Generic 3i Wiring
, 555-204-111). It does not indicate a 
problem with the TN800 circuit pack. This test is useful for verifying the repair of 
the problem
Table 10-50.
TEST #624 Layer 1 Transmission Error Counter Test
Error 
Code
Test 
Result
Description/Recommendation
2000
ABORT
Response was not received from the circuit pack within the allowable time 
period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit 
pack using the 
busyout board PCSS
 and 
reset board PCSS
 
commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The TN800 circuit pack is still detecting errors of this type. The Error Code 
field contains the value of this counter.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, review the results of other tests in the Long 
Test Sequence. Note the results of the Level 1 Status Inquiry test. 
Follow the repair procedures for any of the executed tests if they fail. 
Otherwise, go to the next step.
3. Replace the circuit pack.
PASS
The Layer 1 Transmission error counter was read correctly and has a value 
of 0.
Continued on next page