DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-145
BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack) 
10
BRI-BD/LGATE-BD (ISDN-BRI Line 
Circuit Pack)
NOTE:
Some of the information in this section is reserved for future use.
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included 
in Chapter 9, "Packet Bus Fault Isolation and Correction". This flowchart, 
along with the other information presented in the chapter, can help in 
resolving problems that involve more than a single station or circuit pack. 
Whenever the repair procedures for this Maintenance Object refer to 
Packet Bus and/or Packet Control maintenance, be sure to reference 
Chapter 9, "Packet Bus Fault Isolation and Correction", in addition to the 
relevant MO documentation.
ISDN-BRI Line is a packet port circuit pack that provides access to ISDN-BRI 
endpoints. The ISDN-BRI Line circuit pack supports 12 ports, each of which 
provides access to ISDN stations. Voice and circuit-switched data from the ISDN 
stations are carried on the Time Division Multiplex (TDM) Bus. Signaling is 
carried over the Packet Bus.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (A, B, C, D, or E); and SS is the address of the slot in the carrier where the 
circuit pack is located (01, 02, ..., etc.).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
Full Name of MO
BRI-BD
MAJOR
test board PCSS l
ISDN-BRI Line 
Circuit Pack
BRI-BD
MINOR
test board PCSS l
ISDN-BRI Line 
Circuit Pack
BRI-BD
WARNING
test board PCSS sh
ISDN-BRI Line 
Circuit Pack
LGATE-BD
MAJOR
test board PCSS l
DEFINITY Lan 
Gateway
LGATE-BD
MINOR
test board PCSS l
DEFINITY Lan 
Gateway
LGATE-BD
WARNING
test board PCSS sh
DEFINITY Lan 
Gateway