DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-154
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
BRI-PORT (ISDN-BRI Port),
ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:
Some of the information in this section is reserved for future use.
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included 
in Chapter 9, "Packet Bus Fault Isolation and Correction". This flowchart, 
along with the other information presented in the chapter, can help in 
resolving problems that involve more than a single station or circuit pack. 
Whenever the repair procedures for this Maintenance Object refer to 
Packet Bus and/or Packet Control maintenance, be sure to reference 
Chapter 9, "Packet Bus Fault Isolation and Correction" in addition to the 
relevant MO documentation.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (A, 
B, C, D, or E); and SS is the address of the slot in the carrier where the circuit pack is located (01, 
02, ..., etc.); and pp is the 2-digit port number (for example, 01).
2.
The alarm level for ASAI and AT&T adjunct ports may be administered using the 
set options
 
command. The alarm level can be set independently for Off-Board and On-Board alarms to 
WARNING, MINOR, or MAJOR for all ASAI and AT&T adjunct ports in the system.
3.
All alarming for an ASAI and AT&T adjunct and OFF-BOARD alarming for an ASAI or AT&T port is 
disabled if the ASAI or AT&T adjunct asks the switch to suspend maintenance. When this occurs, 
an error and a WARNING alarm is logged against the ASAI or AT&T adjunct. The Hardware Error 
and Alarm Logs should be checked to see if the adjunct has disabled alarming.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
Full Name of MO
BRI-PORT
MINOR
test port PCSSpp l
ISDN-BRI Port
BRI-PORT
WARNING
test port PCSSpp sh
ISDN-BRI Port
ABRI-PORT
MAJOR
2
,
3
test port PCSSpp l
ASAI ISDN-BRI Port
ABRI-PORT
WARNING
2
,
3
test port PCSSpp l
ASAI ISDN-BRI Port
ATT-PORT
MAJOR
2
3
test port PCSSpp l
AT&T Adjunct ISDN-BRI Port
ATT-PORT
WARNING
2
3
test port PCSSpp l
AT&T Adjunct ISDN-BRI Port
LGATE-PORT
MAJOR
2
3
test port PCSSpp l
Ethernet ASAI Port
LGATE-PORT
WARNING
2
3
test port PCSSpp l
Ethernet ASAI Port
ATTE-PT
MAJOR
2
3
test port PCSSpp l
Ethernet AT&T Adjunct Port
ATTE-PT
WARNING
2
3
test port PCSSpp l
Ethernet AT&T Adjunct Port