Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-157
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Table 10-55.
ISDN-BRI Port Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level 
BRI-PORT
Alarm Level 
ABRI-PORT 
ATT-PORT 
LGATE-PORT 
ATTE-PT
On/ 
Off 
Board
Test to Clear 
Value
0
1
0
Any
Any
Any
Any
test port 
PCSSpp sh r 1
1 (a)
(a)
Level 1 Status 
Inquiry (#621)
WRN
MAJ/MIN/ WRN
2
OFF
test port 
PCSSpp sh r 2
18
busyout port 
PCSSpp
WRN
OFF
release port 
PCSSpp
130 (b)
WRN
ON
test port PCSS 
sh
257 (c)
(c)
EPF Inquiry 
(#622)
WRN
MAJ/MIN/ WRN
2
OFF
test port 
PCSSpp sh r 1
513 (d)
(d)
none
(d)
(d)
ON
769 (e)
0
none
WRN
MAJ
OFF
1281 (f)
NPE Crosstalk 
(#617)
MIN/ WRN
2
ON
test port 
PCSSpp l r 2
1537 (g)
46210
CRC Error 
Counter (#623)
WRN
MAJ/MIN/ WRN
2
OFF
1793 (h)
BRI Port Local 
TDM
MIN/ WRN
2
ON
test port 
PCSSpp l r 2
Loop Around 
(#619)
3841 (i)
46208
None
3842 (j)
0
None
3843 (k)
0
None
3844 (l)
46223
None
Continued on next page