DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-161
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
NOTE:
The NPE Crosstalk Test and the BRI Port Local TDM Loop Around Test are 
not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT.
NPE Crosstalk Test (#617)
This test is destructive
.
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain and provides conferencing functions on 
a per-port basis. The NPE Crosstalk Test verifies that this port’s NPE channel 
talks on the selected time slot and never crosses over to time slots reserved for 
other connections. If the NPE is not working correctly, one-way and noisy 
connections may be observed. This test is part of a port’s Long Test Sequence 
and takes approximately 20 to 30 seconds to complete. Crosstalk testing is 
performed on both B-channels (B1 and B2) associated with a BRI port. If this test 
fails on either channel, any endpoints connected to the port are taken 
out-of-service.
This test is not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT because 
the B-channels associated with the port are not used by ASAI or AT&T adjuncts.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Crosstalk Test (#617)
X
D
BRI Port Local LAN Loop Around Test (#618)
X
D
BRI Port Local TDM Loop Around Test (#619)
X
D
Electronic Power Feed Restoral Test (#620)
X
X
ND
Level 1 Status Inquiry Test (#621)
X
X
ND
Electronic Power Feed Inquiry Test (#622)
X
X
ND
CRC Error Counter Test (#623)
X
ND
Layer 1 Transmission Error Counter Test (#624)
X
ND
Receive FIFO Overflow Error Counter Test (#625)
X
ND
Clear Error Counters (#270)
X
X
ND