DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-169
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Level 1 Status Inquiry Test (#621)
This test determines the state of the transmission facility of a BRI port at the 
physical layer (that is, Level 1). Level 1 can be in one of three possible states: 
Activated, Pending Activation, or Deactivated.
The Activated state is the correct state for an ISDN-BRI port. In this state the 
Level 1 interface can communicate with the BRI endpoint or ASAI or AT&T 
adjunct administered on this port. This test passes if the state of Level 1 (L1) is 
Activated. This test also passes if software has taken this port out of service. See 
the description of the Level 1 "Deactivated State" below for more details.
The Pending Activation state indicates a problem with the endpoints or adjunct, 
the wiring to the sets or adjunct, or the BRI-LINE circuit pack. When in this state, 
the Level 1 interface is either not receiving any L1 framing from the endpoint or 
adjunct (Endpoint Idle), or it is communicating with the endpoint or adjunct but 
cannot transition to the Activated state (Endpoint Active).
Table 10-59.
TEST #620 Electronic Power Feed Restoral
Error 
Code
Test 
Result
Description / Recommendation
1005
ABORT
This test is not valid for this port type. The TN2208 does not 
have an electronic power feed, and the test will abort.
2012
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a maximum of 
five times.
2. If the test continues to abort, escalate the problem.
PASS
The EPF Test passed. The message to turn on the power feed 
to the station or the adjunct was successfully sent to the port.
1. Although this test should not return a fail result, after 
running this test, the Error Log should be checked for any 
entries with error type 257 to examine the real results of 
this test.
2. An error type of 257 in the Error Log indicates some 
problem with the power to the station or the adjunct. 
Check for a short in the wiring, a damaged jack, a 
defective voice terminal or adjunct, or an incorrect type of 
terminal.
Continued on next page