DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-238
CARD-MEM (Memory Card) 
10
Memory Card Match Test (#697)
This test is a nondestructive test. The test verifies the inserted memory card for 
consistency with the system configuration. The test helps answer the following 
questions:
Is the inserted memory card a system software upgrade card?
Does the size of the inserted memory card match the capacity of the 
system configuration?
Table 10-83.
TEST #696 Memory Card Format and Read Test 
Error 
Code
Test 
Result
Description/ Recommendation
2012 
2106 
2114
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2013 
2100 
none
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2108
ABORT
The NETCON circuit pack is not a TN777B circuit pack.
1. Follow the Standard Repair Procedures for replacing the NETCON 
circuit pack with the TN777B circuit pack.
2. Re-enter the 
test card-mem
 command.
2110
ABORT
No memory card is inserted.
1. Insert a formatted memory card into the slot at the TN777B NETCON 
circuit pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2113
ABORT
One of the two directories in the memory card is corrupted.
1. Re-enter the 
test card-mem
 command, and verify that Test #699 
passes.
2. If the test is aborted again with this error code, replace the memory 
card.
FAIL
System software cannot recognize the inserted memory card. The memory 
card is not formatted, or the directories of the memory card are corrupted.
1. Replace the memory card with a new formatted memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
System recognizes the inserted memory card, and it can read the 
directories from the memory card.