Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-296
CO-DS1 (DS1 CO Trunk) 
10
DS1 CO Dial Tone Seizure Test (#314)
DS1CO Dial Tone Seizure Test checks the trunk’s signaling capability provided 
by the DS1 Interface circuit pack. The maintenance software initiates the test by 
sending a "seizure" message to the DS1 Interface circuit pack and expects an 
"active" reply from the DS1 interface circuit pack. If the "active" message is 
received, then the test passes. If no message is received and the timer expires, 
the test is aborted. If the DS1 Interface circuit pack sends a "reorder" message 
back to maintenance software, then the test fails.
The test 
CANNOT
 be run on a trunk if one of the following cases is true:
a. The trunk direction is administered as an incoming only trunk.
b. The trunk has been seized by a normal trunk call.
c. The trunk is administered with maintenance test disabled.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This result 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, an insane board is inserted, or the board is hyperactive 
(see note below).
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, dispatch to check to ensure that there is a valid board 
inserted.
Hyperactivity causes some special problems with the sequence suggested 
above. If the ports are translated after issuing the 
list config
 command but 
the ’Vintage’ field reports that there is no board (when there really is a 
board), then the 
busyout board
 and the 
release busy board
 commands 
will not work (even though the 
reset board
 command will work). The 
software will put the hyperactive board back in service after the 
hyperactivity clears.
Table 10-97.
TEST #36 Port Audit and Update Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page