Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-303
CO-TRK (CO Trunk) 
10
3. PBX On-Hook first (Drop Message): Open the Tip-Ring Loop, no loop 
current
a. CO Response: Open circuit on Tip
4. CO On-Hook first (Disconnect): Open circuit on Tip, no loop current
Hardware Error Log Entries and Test to Clear 
Values
Table 10-99.
CO Trunk Error Log Entries 
Error Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
57347
None
15 (b)
any
Port Audit Update 
Test (#36)
18
0
busyout trunk 
<grp>/<mbr>
WARNING
OFF
release trunk 
<grp>/<mbr>
130(c)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (a)
50176
None
513 (a)
57364
None
MAJ/MIN/ 
WRN
2
ON
769 (a)
57392
None
MAJ/MIN/ 
WRN
2
OFF
1025 (e)
Any
Demand Diagnostic 
Test (#3)
MAJ/MIN/ 
WRN
2
OFF
test port PCSS sh r 2
1281 (e)
Any
Demand Diagnostic 
Test (#3)
MAJ/MIN/ 
WRN
2
ON
test port PCSS sh r 3
1537
Dial Tone Test (#0)
MAJ/MIN/ 
WRN
2
OFF
test port PCSS l r 2
1793
Loop Around and 
Conference Test 
(#33)
MAJ/MIN/ 
WRN
2
ON
test port PCSS l r 3
2049
NPE Cross Talk Test 
(#6)
MAJ/MIN/ 
WRN
2
ON
test port PCSS l r 3
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
Continued on next page