Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-308
CO-TRK (CO Trunk) 
10
2. At the administration terminal, busyout the affected port, and run a Long 
Test Sequence. If Dial Tone Test #0 passes, ignore this error. Release the 
port.
3. At the administration terminal, busyout the affected port, and run a Long 
Test Sequence. If CO Demand Diagnostic Test #3 passes and this error 
keeps occurring, refer problems to CO. Release the port.
4. If the error count associated with this error type is very high (that is, 255) 
and all tests pass, then either the reverse current detector is defective or 
the CO line is noisy. If the CO line is suspected, Tip and Ring observations 
should be made. If the line is determined to be noisy, the problem should 
be referred to the CO. If the reverse current detector is defective, ignore 
this error.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence.
For example, you may also clear errors generated from other tests in the testing 
sequence.
Notes:
a. A demand test of Diagnostic Test (#3) always returns a PASS indication for 
CO-TRK/CO-BD [TN747B] version 8 or greater. However, any errors 
produced as a result of this test are logged and produce no alarms.
If errors logged by Test #3 are the only complaints against this trunk, then 
the system technician person should check if MFT/Range Extenders are 
being used. If extenders are present, then there is a good chance that 
there is excessive loop current, which causes Test #3 to log errors.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Dial Tone Test (#0)
X
ND
CO Demand Diagnostic Test (#3) (a)
X
X
ND
Loop Around and Conference Test (#33)
X
ND
Audit Update Test (#36)
Analog Transmission Test (#844-848) (b)
X
(c)
X
(c)
ND