Near End Line Statistics—Totals
268
Access Server Administrators’ Reference Guide 
22 • T1/E1 Link
Controlled Slip Seconds (dsx1IntervalCSSs)
The number of controlled slip seconds encountered by a DS1 interface in one of the previous 96, individual 
15-minute, intervals.
Path Code Violations (dsx1IntervalPCVs)
The number of path coding violations encountered by a DS1 interface in one of the previous 96, individual 
15-minute, intervals.
Line Errored Seconds (dsx1IntervalLESs)
The number of line errored seconds encountered by a DS1 interface in one of the previous 96, individual 15-
minute, intervals.
Bursty ErroredSeconds (dsx1IntervalBESs)
The number of bursty errored seconds (BESs) encountered by a DS1 interface in one of the previous 96, indi-
vidual 15-minute, intervals.
Degraded Minutes (dsx1IntervalDMs)
The number of degraded minutes (DMs) encountered by a DS1 interface in one of the previous 96, individual 
15-minute, intervals.
Line Code Violations (dsx1IntervalLCVs)
The number of line code violations (LCVs) encountered by a DS1 interface in the current 15-minute interval.
Near End Line Statistics—Totals
Click on Near End Line Statistics—Totals to display the total statistics of errors that occurred during the previ-
ous 24-hour period (see 
Figure 111. Totals of Near End Performance window
Errored Seconds (dsx1TotalESs)
The number of errored seconds encountered by a DS1 interface in the previous 24-hour interval.