Far End Line Statistics—History
271
Access Server Administrators’ Reference Guide 
22 • T1/E1 Link
Path Code Violations (dsx1FarEndCurrentPCVs)
The number of far-end path coding violations reported via the far-end block error count encountered by a 
DS1 interface in the current 15-minute interval.
Bursty Errored Seconds (dsx1FarEndCurrentBESs)
The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in the current 15-
minute interval.
Degraded Minutes (dsx1FarEndCurrentDMs)
The number of far-end degraded minutes (DMs) encountered by a DS1 interface in the current 15-minute 
interval.
Far End Line Statistics—History
Click on Far End Line Statistics—History to display far-end statistics for previously completed 15-minute 
intervals (see 
Figure 113. History of Far End Performance window
Far End Interval (dsx1FarEndIntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least 
recently completed 15-minutes interval (assuming that all 96 intervals are valid).
Errored Seconds (dsx1FarEndIntervalESs)
The number of far-end errored seconds encountered by a DS1 interface in one of the previous 96, individual 
15-minute, intervals.