3 • Configuring the RAS for operation
Model 3125 RAS Getting Started Guide
54
Configuring the RAS with a Web browser
– dsx1D4 AT&T D4 format DS1
– For ISDN PRI service, set the line type to dsx1ESF
2. Click on the 
Line Coding
 pop-up menu (see figure 33 on page 49). The most common options are: 
dsx1B8ZS and dsx1AMI. For ISDN PRI service, set the line coding to dsx1B8ZS.
3. Click on the 
Line Build Out
4. Click on the 
Yellow Alarm Format
 pop-up menu and choose linkYellowFormatBit2(1).
5. Click on 
Submit Query
.
At this point, the WAN front panel LEDs will become active. A solid green FRAME light indicator means that 
the RAS has synchronized with the T1 line. 
Note
If you suspect that there is a physical malfunction in the WAN ports, 
you can assemble a loopback connector to test the port (see figure 34 
on page 50).
Setting the line signaling for an ISDN/PRI line
Do the following:
1. Scroll down the 
WAN Circuit Configuration 
window, until the signaling Settings section appears (see 
2. Click on the 
Signal Mode
 pop-up menu and choose messageOriented(4).
3. Click on the 
Message Oriented Switch Type
ni1(National ISDN 1), dms(Nortel Switch) or att(AT&T Customer).
4. Click on 
Submit Query
.
Signaling is now configured for ISDN/PRI.
Setting the line signaling for a robbed-bit T1 line 
Do the following:
1. Scroll down the 
WAN Circuit Configuration 
window, until the signaling Settings section appears (see 
2. Click on the 
Signal Mode
 pop-up menu and choose robbedBit(3).
3. Click on 
Submit Query
.
4. Click on the 
Robbed-Bit signaling Protocol
 pop-up menu and choose LinkGroundStart, LinkLoopStart, or 
LinkEMWinkStart.
5. Click on 
Submit Query
.
6. Click on the 
Yellow Alarm Format
 pop-up menu and choose one of the following options:
– For T1 lines with D4/AMI settings, this should be set to linkYellowFormatBit(1).