Enter the Username and Password used to login into the RPC  (Note that these login credentials 
are not related to the Users and access privileges you configured in Serial & Networks: Users & 
Groups). 
 
If you selected SNMP protocol, enter the SNMP v1 or v2c Community for Read/Write access (by 
default this would be “private”). 
 
Check Log Status and specify the Log Rate (minutes between samples) if you want the status 
from this RPC to be logged. View these logs from the Status: RPC Status screen. 
 
Click Apply. 
 
For SNMP PDUs, the console server probes the configured RPC to confirm the RPC Type matches 
and reports the number of outlets it finds that can be controlled.  If unsuccessful, it will report 
Unable to probe outlets and you’ll need to check the RPC settings or network/serial connection. 
 
For serially connected RPC devices, a new Managed Device (with the same name as given to the 
RPC) will be created. The console server will then configure the RPC with the number of outlets 
specified in the selected RPC Type or will query the RPC itself for this information. 
Note 
The Black Box console servers support most popular network and serial PDUs. If your PDU is not 
on the default list, then you can add support directly (as covered in Chapter 14—Advanced 
Configurations) or add the PDU support to either the Network UPS Tools or PowerMan open 
source projects. 
Configure IPMI service processors and BMCs so that all authorized users can use the 
Management Console to remotely cycle power and reboot computers, even when their operating 
system is unresponsive. To set up IPMI power control, the Administrator  first enters the IP 
address/domain name of the BMC or service processor (for example, a Dell DRAC) in Serial & 
Network: Network Hosts,
  then in Serial & Network: RPC Connections  specifies the RPC 
Type
 to be IPMI1.5 or 2.0. 
 
 
8.1.2  RPC access privileges and alerts  
You can now set PDU and IPMI alerts using Alerts & Logging: Alerts (refer to Chapter 7). You can also 
assign which user can access and control which particular outlet on each RPC using Serial & Network: 
User & Groups (refer Chapter 4). 
 
8.1.3  User power management  
The Power Manager enables both Users and Administrators to access and control the configured serial 
and network attached PDU power strips, and servers with embedded IPMI service processors or BMCs. 
 
Select the Manage: Power and the particular Target power device to be controlled (and the 
Outlet to be controlled if the RPC supports outlet level control). 
 
The outlet status is displayed and you can initiate the Action you want to take by selecting the 
appropriate icon: 
 
Turn ON 
_____________________________________________________________________ 
 
 
724-746-5500 | blackbox.com
 