VDC connector from the power supply plugs into the 12VDC (PWR) power socket on the side of the 
LES1508A. 
 
2.2.2  LES1408A - LES1448A, LES1308A- LES1348A and LES1208A - LES1248A power 
The Advanced Console Server models (LES1208A-R2, LES1216A-R2, LES1232A, LES1248A-R2, LES1308A, 
LES1316A, LES1332A, LES1348A, LES1408A, LES1416A, LES1432A and LES1448A) all have dual universal 
AC power supplies with auto failover built in.  These power supplies each accept AC input voltage 
between 100 and 240 VAC with a frequency of 50 or 60 Hz. The total power consumption per console 
server is less than 30W. Two IEC AC power sockets are located at the rear of the metal case, and these 
IEC power inlets use conventional IEC AC power cords. 
 
Power cords for various regions are available, although the North American power cord is provided by 
default. There is a warning notice printed on the back of each unit. 
 
 
To avoid electrical shock, connect the power cord grounding conductor to 
ground! 
 
 
2.2.2  LES1116A, LES1132A and LES1148A power 
The  LES1116A, LES1132A and LES1148A models have a built-in universal auto-switching AC power 
supply. This power supply accepts AC input voltage between 100 and 240 VAC with a frequency of 50 or 
60 Hz. The power consumption is less than 20W.  
  
 
 
The LES1116A, LES1132A and LES1148A models have an IEC AC power socket located in the rear of the 
metal case. This IEC power inlet uses a conventional IEC AC power cord, and the power cords for various 
regions are available. Call Black Box Technical Support for details at 724-746-5500. (The North American 
power cord is provided by default.) There is a warning notice printed on the back of each unit. 
 
 
To avoid electrical shock, connect the power cord grounding conductor to 
ground. 
 