4.1.4  Device (RPC, UPS, EMD) Mode 
This mode configures the selected serial port to communicate with a serial controlled Uninterruptable 
Power Supply (UPS), Remote Power Controller/Power Distribution Unit  (RPC) or Environmental 
Monitoring Device (EMD). 
 
 
Select the desired Device Type (UPS, RPC or EMD) 
 
Proceed to the appropriate device configuration page (Serial & Network: UPS Connections, RPC 
Connection or Environmental) as detailed in Chapter 8—Power & Environmental Management. 
 
4.1.5  Terminal Server Mode   
 
Select  Terminal Server Mode  and the Terminal Type  (vt220, vt102, vt100, Linux, or ANSI) to 
enable a getty on the selected serial port. 
 
The getty will then configure the port and wait for a connection to be made. An active connection on a 
serial device is usually indicated by the Data Carrier Detect (DCD) pin on the serial device being raised. 
When a connection is detected, the getty program issues a login: prompt, and then invokes the login 
program to handle the actual system login.  
Note 
Selecting Terminal Server mode will disable Port Manager for that serial port, so data is no longer 
logged for alerts, etc.  
 