Brocade Communications Systems 4424 ユーザーズマニュアル

ページ / 48
4
4424 Blade Server SAN I/O Module Hardware Reference Manual
53-0000571-01
Hardware Description
1
For static POD, 
 shows the base internal and external ports that are licensed, as well as 
the additional 12 ports that can be activated with a POD license. For details about activating 
and deactivating additional ports when you have POD licensing, refer to 
Hardware Description
This section describes the physical SAN I/O Module as shipped from the factory. For specifications, 
such as installed memory, weight and physical dimensions, facility requirements, architectural 
specifications, and regulatory compliance, refer to 
Port side 
Externally accessible ports and LEDs are on the port side of the SAN I/O Module. The port side 
faces out when the SAN I/O Module is inserted into the I/O bay of the Blade Server enclosure. 
 details the port side. For a complete description of the locations and interpretations of 
these LEDs, see 
Access the I/O module handle at the front of the port side of the SAN I/O Module. By lifting the 
handle’s release latch, you can open the handle to remove and insert the unit from the Blade 
Server Enclosure.
FIGURE 1
Port Side View
1. Ports with port status and port speed LEDs
2. RJ45 console port
3. SAN I/O Module status LED
4. Power status LED
5. Server management LED
6. SAN I/O Module handle
TABLE 1
Ports available 
Port Licensing
External Ports
Internal Ports
Base
17, 18, 19, and 20
1, 2, 3, 4, 5, 6, 7, and 
8
POD
0, 21, 22, and 23
9, 10, 11, 12, 13, 14, 
15, and 16
IOIOI
1
2
3
4
5
6