4424 Blade Server SAN I/O Module Hardware Reference Manual
13
53-0000571-01
Connecting the SAN I/O Module to the Ethernet network
2
Connecting the SAN I/O Module to the Ethernet network
Once you have successfully set the appropriate IP address of the SAN I/O Module, you can 
establish an Ethernet connection through the Chassis Management Controller (CMC) to a remote 
management workstation for any additional configuration. The management workstation must be 
on the same Ethernet subnet as the CMC.
NOTE
Ensure that the SAN I/O Module is not being modified from any other connection until configuration 
is complete.
Connecting the SAN I/O Module to the fabric
NOTE
Refer to 
 on page 8 before beginning the following procedure.
Before beginning the following steps, determine whether the SAN I/O Module is in Access Gateway 
or Full Fabric Switch mode. This affects the configuration process. Using the SAN I/O Module CLI, 
you can enter the ag ––modeShow command to determine the current operating mode.
1. If the SAN I/O Module is in Full Fabric Switch mode, continue with 
. If the 
Module is in Access Gateway Mode, go on to 
2. Log onto the SAN I/O Module through a Telnet connection, using the admin account. 
3. Modify the domain ID if required using SAN I/O Module CLI commands. 
The default domain ID is 1. If the SAN I/O Module is not powered on until after it is connected 
to the fabric and the default domain ID is already in use, the domain ID for the new SAN I/O 
Module is automatically reset to a unique value. If the SAN I/O Module is connected to the 
fabric after it has been powered on and the default domain ID is already in use, the fabric 
segments.
To find the domain IDs that are currently in use, run the fabricShow command on another SAN 
I/O Module in the fabric. Identify an unused domain ID:
a. Disable the SAN I/O Module being configured using the switchDisable command.
b. Enter the configure command.
The command prompts display sequentially. Enter a new value or press Enter to accept 
each default value. The SAN I/O Module now has a unique domain ID and can join the 
fabric. Following is an example of command output.
SW48000_155:root> configure
    Data field size: (256..2112) [2112]
    Sequence Level Switching: (0..1) [0]
    Disable Device Probing: (0..1) [0]
    Suppress Class F Traffic: (0..1) [0]
    Switch PID Format: (1..2) [1]Configure...
  Fabric parameters (yes, y, no, n): [no] y
    Domain: (1..239) [1] 155
    R_A_TOV: (4000..120000) [10000]