4 Replacement Procedures  
4.31  Fluorescent Lamp 
Satellite R10 Maintenance Manual (960 -509)  
 
4-69 
4.31  Fluorescent Lamp 
This system uses LCD modules from the following suppliers. The procedure for replacing 
the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure. 
 
Type 
Part. No 
Supplier 
Section 
14.1 inch 
G33C0002J110 
CMO  
4.31.1  
 
 
 
 
Note: - When working with an LCD module, always use a flat, grounded table. 
   
- Handle the backlight unit in the environment without dust, such as on the clean 
bench. Keep the work table free from any screws or other material that may 
scratch the LCD surface. 
   
- Use an anti-static or protective sheet. 
   
- When replacing the FL unit, cover with a finger protector or similar to prevent 
dirtying or scratching the LCD panel. 
   
- Take care when handling the lamp. Excessive force may break the lamp. 
   
- Take care not to dirty or deform the lamp reflector. 
   
- Ensure a lways that the power of the LCD module is turned off before 
connecting or disconnecting cables and connectors.