Avocent AutoView 3200 Digital KVM Switch AV3200-201 ユーザーズマニュアル

製品コード
AV3200-201
ページ / 185
64        AutoView 3100/3200 Switch Installer/User Guide
Other Console Main Menu Options
Besides the Network Configuration option, the Console Main menu features the following menu 
items: Security Configuration, Firmware Management, Enable Debug Messages, Restore Factory 
Defaults, Reset Appliance and Exit. Each is discussed in this section.
Security configuration
The AutoView 3100/3200 switch contains an internal database that may be used by the AutoView 
Remote Operations software, the local port or the CONSOLE port if the DSView software server 
is unavailable. 
The Security Configuration menu contains the following options:
Local User Accounts: Add, edit or delete users to and from the AutoView 3100/3200 
switch database.
Console Password: Enable or disable using security for the console (access requires an 
 
Admin account).
Local user accounts
NOTE: When you use the options to add, edit or delete a user, a list of existing users will appear. You may enter 
N to display the next page of users in the database or enter P to go back to the previous page of users.
To add a user to the AutoView 3100/3200 switch database:
1.
Type 
2
 and press 
Enter
 to access the Security Configuration menu option.
2.
Type 
1
 and press 
Enter
 to access the Local User Accounts menu option. A list of users already 
within the database will appear.
3.
Type 
A
.
4.
When prompted, type the username you wish to add and press 
Enter
.
5.
You will be prompted to type a password for the user. Type a password and press 
Enter
.
6.
You will be prompted to re-type the password. Type the password again and press 
Enter
7.
Enter
 0
 (zero) to exit.
To rename a user in the AutoView 3100/3200 switch database:
1.
From the Console Main menu, type 
2
 and press 
Enter
 to access the Security Configuration 
menu option.
2.
Type 
1
 and press 
Enter
 to access the Local User Accounts menu option. A list of users already 
within the database will appear.
3.
Type 
E
.