Konica Minolta MS6000 MKII ユーザーズマニュアル

ページ / 102
2. Initial Settings
4-11
Mi
s
c
e
llaneo
us
Ch
apte
r 4
U8: Total Scan Counter
The number of scan sequences carried out by the Scanner can be displayed with this func-
tion.
1. Select U8 in the User mode.
2. Press the Start key.
The number of scan sequences so far carried out by the Scanner is displayed.
The following display represents that the scan count is 24,612.
System Settings by the dealer
System Settings
Description
Selection
Initial Setting
Auto reset
Setting changes made to the control panel 
that are not used within 60 seconds of 
being input are automatically cancelled 
and the system reverts back to the original 
settings.
Enabled
* (200V)
Disabled
* (120V)
Auto Power Save 
ON/OFF
Sets the unit to enable or disable the Auto 
Power Save mode.
* For USA and Canada (120V area), the 
Auto Power Save mode becomes avail-
able only if the Energy Star Kit is 
mounted on the Scanner.
Enabled
Disabled
* (200V)
* (120V)
Printer Heater 
OFF (PR mode 
only)
Turns the Printer’s heater OFF if the sys-
tem is left idle for a specific period of 
time.
* Priority is given to the Power Save 
mode, if Power Save has been set.
Disabled
30 min.
*
60 min.
Auto Projection 
Lamp OFF
Turns the Scanner’s Projection Lamp OFF 
if the system is left idle for a specified 
period of time.
* Priority is given to the Power Save 
mode, if Power Save has been set.
Disabled
*
30 min.
60 min.
Fine mode con-
trast select
Applies the following functions as required:
Contrast Emphasis: applied when film con-
tains text that is poorly contrasted against its 
background making it difficult to read.
Outline Emphasis: applied when film con-
tains blurred black and white images.
Contrast 
Emphasis
*
Outline 
Emphasis