Metrologic Instruments IS1650 ユーザーズマニュアル

ページ / 52
 
 
36 
 
S
CANNER AND 
C
ABLE 
T
ERMINATIONS
 
 
S
CANNER 
P
INOUT 
C
ONNECTIONS
 
 
 
 
IS1650-14 
RS232 
Pin 
Function 
1 Ground 
RS232 Transmit Output 
RS232 Receive Input 
4 RTS 
Output 
5 CTS 
Input 
6 DTR 
Input 
7 Reserved 
8 Reserved 
9 +5VDC 
The IS1650 scanner interfaces 
terminate to a 10-pin, RJ45 
Female Socket.  The serial 
number label indicates the 
interface enabled when the 
scanner is shipped from the 
factory.   
 
 
10 Shield 
Ground 
 
 
 
 
 
 
 
 
 
 
IS1650-47, Keyboard Wedge &  
Stand-Alone Keyboard 
Pin 
Function 
1 Ground 
RS232 Transmit Output 
RS232 Receive Input 
4 PC 
Data 
5 PC 
Clock 
6 KB 
Clock 
7 PC 
+5V 
8 KB 
Data 
9 +5VDC 
10 Shield 
Ground 
Figure 19.