Motorola MSXX07 ユーザーズマニュアル

ページ / 368
13 - 28 Symbol MiniScan MSXX07 Series Integration Guide
Setup Field(s)
Send Data (continued)
Send Next 19 Characters
Send Next 20 Characters
Table 13-2    
Setup Field(s) Definitions
Parameter
Description
Page
Move Cursor
Move Cursor To a Character
Scan the 
, then any printable ASCII 
character from the 
. This 
moves the cursor to the position after the matching character. If the 
character is not there, the rule fails and ADF tries the next rule.
Move Cursor to Start of Data
Scan this bar code to move cursor to the beginning of the data.
Move Cursor Past a Character 
This action moves the cursor past all sequential occurrences of a 
selected character. For example, if the selected character is ‘A’, then 
the cursor moves past ‘A’, ‘AA’, ‘AAA’, etc. Scan the 
, then select a character from the 
. If the character is not there, the cursor does not move 
(i.e., has no effect).
Skip Ahead “N” Characters
Scan one of these bar codes to select the number of positions ahead 
to move the cursor.
Skip Back “N” Characters
Scan one of these bar codes to select the number of positions back to 
move the cursor.
Send Preset Value
Send Values 1 through 6 by scanning the appropriate bar code. Set 
these values using the prefix/suffix values.
Value 1 = Scan Suffix
Value 2 = Scan Prefix
Values 3-6 are not applicable