Motorola MSXX07 ユーザーズマニュアル

ページ / 368
7 - 8
Symbol MiniScan MSXX07 Series Integration Guide
Symbol MS2207VHD Decode Zones
The decode zone is a function of various symbol characteristics including density, print contrast, wide to narrow 
ratio and edge acurity. Typical values appear
 an
 list the typical and 
guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the 
width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any 
given range appears below. To calculate this distance, see 
.
Symbol MS2207VHD 1D Decode Zone
Figure 7-5    
Symbol MS2207VHD 1D Slab/Raster Decode Distances
In.
cm
0
7.5 mil
55 mil
15.0
Depth of Field
5.25
Note:  Typical performance at 68˚F (20˚C) 
           on high quality symbols in normal room light.
           Vcc = 5V
2.5
5
7.5
10
12.5
0
12.7
25.4
38.1
50.8
63.5
5 mil
4.75
4 mil
4.1
2.0
3.4
15
76.2
6 mil
0
In.      cm
W
i
d
t
h
o
f
F
i
e
l
d
0
2.5
5
7.5
2.5
5
7.5
5.1
10.1
15.2
5.1
10.1
15.2
10
25.4
10 25.4
1.75
1.5
*
* Minimum distance determined by symbol length and scan angle.
MS 220XVHD