Motorola MC1000 ユーザーズマニュアル

ページ / 70
4 - 4
MC1000 with Windows CE 4.2 User Guide
Single Slot Serial/USB Cradle
Table 4-2    
Troubleshooting the Single Slot Serial/USB Cradle
Symptom
Possible Cause
Action
Charge LEDs do not 
light when mobile 
computer or spare Li-ion 
battery is inserted. See 
.
Cradle is not receiving power.
Ensure the power cable is connected securely to both 
the cradle and to AC power.
Mobile computer is not seated 
correctly in the cradle.
Remove and re-insert the mobile computer into the 
cradle, ensuring it is firmly seated. 
Spare Li-ion battery is not 
seated correctly in the cradle.
Remove and re-insert the spare Li-ion battery into the 
charging slot, ensuring it is correctly seated. Note the 
polarity icon on the battery.
Extreme battery temperature.
Li-ion battery does not charge if battery temperature is 
below 32°F (0°C) or above 104°F (40°C).
Mobile computer battery 
is not charging.
Mobile computer was removed 
from cradle or cradle was 
unplugged from AC power too 
soon.
Ensure cradle is receiving power. Ensure mobile 
computer is seated correctly. If a mobile computer 
battery is fully depleted, it can take up to four hours to 
fully recharge the battery.
Battery is faulty.
Verify that other batteries charge properly. If so, 
replace the faulty battery.
Mobile computer is not fully 
seated in the cradle.
Remove and re-insert the mobile computer into the 
cradle, ensuring it is firmly seated. 
Extreme battery temperature.
Li-ion battery does not charge if battery temperature is 
below 32°F (0°C) or above 104°F (40°C).
Spare Li-ion battery is 
not charging.
Li-ion battery not fully seated in 
charging slot. 
Remove and re-insert the spare Li-ion battery into the 
cradle, ensuring it is correctly seated. Note the 
polarity icon on the battery.
Battery inserted incorrectly. 
Ensure the contacts are facing down and toward the 
back of the cradle. Note the polarity icon on the 
battery. Note the polarity icon on the battery.
Battery is faulty.
Verify that other batteries charge properly. If so, 
replace the faulty battery.
Extreme battery temperature.
Li-ion battery does not charge if battery temperature is 
below 32°F (0°C) or above 104°F (40°C).
During data 
communications, no 
data was transmitted, or 
transmitted data was 
incomplete.
Mobile computer removed from 
cradle during communications.
Replace mobile computer in cradle and retransmit.
Incorrect cable configuration.
See the system administrator.
Communications software is not 
installed or configured properly.
Perform setup as described in the MC1000 with 
Windows CE 4.2 Integrator Guide.