TROUBLESHOOTING 
6
 
TROUBLESHOOTING GUIDE 
Problem Suggestion 
On Line Mode and Serial On Line 
the reader does not respond correctly to 
the expected external signal end. 
Mode: 
• 
In the Genius™ software configuration 
program select the OPERATING MODES 
folder and check the “Reading Phase 
Timeout” parameterization. 
Reading: 
it is not possible to read the target 
barcode (always returns No Read) 
ading diagrams)? 
• 
Is the Tilt angle too big? 
• 
Is the Skew angle less than 10° (direct 
reflection)? 
• 
Choose the CODE tab and enable 
different code types (except 
Pharmacode). LENGTH = Variable. 
• 
Is the barcode quality sufficient? 
• 
If you had no success, try to perform the test 
using the BARCODE TEST CHART included 
with the product. 
• 
If working in PackTrack™ mode, verify that 
the coordinates (in particular the Y axis) are 
correct. 
• 
Check synchronization of reading pulse with 
object to read. 
Is the scan l
• 
ine correctly positioned? 
• 
Place barcode in the center of scan line and 
run TEST MODE (selectable by Genius™ as 
Operating Modes). 
If you still have troubles, check the following: 
• 
Is the reading distance within that allowed 
(see re
Communication: 
the device is not transmitting anything to 
the host. 
• 
Is serial cable connected? 
• 
Is correct wiring respected? 
• 
If using MAIN RS232 or RS485 interface, is 
the reference ground connected to proper 
SGND Main Isolated (also referred to as 
GND_ISO)? Be careful that it is not 
completely different from GND power ground.
• 
If using C-BOX 100, be sure the RS485 
termination switch is positioned to OFF. 
• 
Are serial host settings equivalent to serial 
device setting? 
Communication: 
data do not appear on the terminal. 
• 
In the Genius™ program enable the DATA 
COMMUNICATION SETTINGS/MAIN-
AUXILIARY PORT\DATA TX parameter. 
Communication: 
data transferred to the host are 
incorrect, corrupted or incomplete. 
• 
In the Genius™ program select the DATA 
COMMUNICATION SETTINGS/DATA 
FORMAT folder and check for HEADER, 
TERMINATOR, SEPARATOR and FILL 
CHAR values. 
• 
Check the CODE FIELD LENGTH value, too.
• 
Are the COM port parameters correctly 
assigned? 
 
 
73