Usually, settings in the window do not need to be changed, however, need to change when 
the connected COM port differs.  When writing fails frequently, change the baud rate (default 
value of 57600) to a smaller value and try again. 
 
6.  When Write Complete displays in the log display area, it is finished.   
 
7.  Shut down GCFlash. (It is necessary to completely shut down once.) 
 
8.  Turn off the GC-201 controller’s power. 
 
 
9.  Updating the DSP of Axis 2   
With the GC-201 controller’s power turned off, set the jumper switches and DIP switches as 
follows. 
SW2 :  1-ON 
JP1  
:  2-3 Short 
JP2  
:  2-3 Short 
 
 
 
 
 
 
 
 
 
 
10.  Follow instructions 3 to 6. 
11.  Shut down GCFlash and turn off the GC-201 controller’s power. 
 
 
 
 
 
 
12.  With the GC-201 controller’s power turned off, return settings to the jumper switches and DIP 
switches as follows. 
JP1
JP2
SW2 
OFF 
ON 
According to the controller settings, the default state of "2" of SW2 will differ. This is 
regardless of a firmware update. Do not change from the default state.