2.8. Control Specifications 
The controller (GC-201) is operated by: 
•  RS-232C command input 
•  High-speed serial communication 
 
 
RS-232C  
communication command input 
High-speed serial communication 
Features 
- Raster scan and step movement etc. 
can be performed easily. 
 
- In order to obtain synchronization 
with external equipment, operation 
can be started with an external 
trigger signal. (Fluctuating delays 
may occur within the internal control 
sampling time.) 
 
 
 
- Vector scans with control over the 
desired locations of two axes are 
possible. This is used in laser 
marking etc. 
 
- Complete synchronization with 
external equipment can be obtained 
in order to use high-speed serial 
communication clock pulses by 
controlling the controller. 
 
- As it can be operated with XY2-100 
communication specifications, a 
controller compliant with XY2-100 
can be connected. 
Target position 
command 
RS-232C communication command 
High-speed serial communication 
 
Operation 
setting 
parameter 
setting 
RS-232C communication command 
RS-232C communication command 
Control clock 
Uses the controller GC-201 internal 
circuit clock pulses 
Uses high-speed serial 
communication clock pulses 
 
 
- A target position command input by an RS-232C communication command, or a target position 
command from a high-speed serial communication can be mutually switched with a command. (See 